0026S1664-9
KEIN LAGERBESTAND
Volumen-Preise
1 | 33,03 € / M |
76 | 31,56 € / M |
152 | 30,88 € / M |
305 | 29,59 € / M |
762 | 28,99 € / M |
Standort Lager
Arizona | 0 M |
Queretaro | 0 M |
Tennessee | 0 M |
Texas | 0 M |
Haftungsausschluss
Die Abbildungen dienen als allgemeine Referenz und stellen möglicherweise nicht die tatsächliche Teilenummer dar. Nicht alle Produkte sind für jedes Land oder jeden Kunden verfügbar. Der Lagerbestand wird täglich aktualisiert. Für Lagerbestände gilt: Zwischenverkauf vorbehalten.
Item Description | The Raychem Cheminax 100 Ohm AWG 26 Twinaxial Cable is specifically designed for outer space applications. Featuring silver-coated high strength copper conductors and a radiation-crosslinked ETFE jacket, this cable ensures superior performance and durabil |
Price Unit | MFT |
Hersteller | TE Connectivity |
Lead Time (Days) | 121 |
Capacitance | 16 |
Hersteller | TE Connectivity |
Gewicht | 14.6 |
Dielectric | Radiation-Crosslinked, Modified ETFE (Dual Extruded) Colors - Light Blue/White |
Jacket Type | Radiation-Crosslinked, Modified ETFE |
Impedanz | 100 |
Temp | -65 |
Schild | S - Single SPC Round |
Conductor Count | 2 |
Innenleiter | Silver-Coated High Strength Copper Alloy |
Product Overview
The Raychem Cheminax 100 Ohm, AWG 26 Twinaxial Cable, part number 0026S1664-9, is meticulously engineered for use in outer space environments. This specification control drawing, identified as Revision C dated 12-11-08, outlines the construction, electrical characteristics, and additional requirements that ensure the cable's performance and reliability under extreme conditions.
Key Specifications
- Impedance: 100 ± 10 ohms (measured at 1 MHz)
- Mutual Capacitance: 16.0 pF/ft (nominal)
- Conductors: AWG 26, 19 strands of AWG 38, silver-coated high strength copper alloy
- Dielectrics: Radiation-crosslinked, modified ETFE, dual extruded with light blue/white colors
- Shield: AWG 38, silver-coated copper
- Outer Jacket: Radiation-crosslinked, modified ETFE, white color (designated by "-9" suffix)
Construction Details
Component Wire Prior to Cabling:
- Crosslink Proof: Insulation at 300 ± 3°C for 1 hour, with dielectric test at 2.5 kV.
- Elongation: Minimum 50%
- Tensile Strength: Minimum 5000 lbf/in²
- Insulation Flaws: Spark test at 3.0 kV (rms) and impulse test at 8.0 kV (peak)
- Insulation Resistance: Minimum 5000 megohms for 1000 ft
- Low Temperature-Cold Bend: -65 ± 3°C for 4 hours, with dielectric test at 2.5 kV
- Shrinkage: Maximum 0.125 inch in 12 inches at 200 ± 3°C for 1 hour
Finished Cable:
- Blocking: 200°C for 6 hours
- Crosslinked Verification: 300 ± 5°C for 6 hours, 6.00 inch mandrel
- Flammability: 3 seconds maximum with no flaming of facial tissue
- Jacket:
- Elongation: Minimum 50%
- Tensile Strength: Minimum 5000 lbf/in²
- Flaws: Spark test at 1.0 kV (rms) and impulse test at 6.0 kV (peak)
- Thickness: Minimum 0.005 inch, nominal 0.008 inch
- Low Temperature-Cold Bend: -55 ± 5°C for 4 hours, 6.00 inch mandrel
- Shield Coverage: Minimum 90%
- Voltage Withstand (Dielectric): 1500 volts (rms)
- Weight: Nominal 14.6 lbs/1000 ft
Outer Space Requirements
- Radiation Resistance: 500 megarads with 1.0 kV dielectric test
- Vacuum Stability:
- Total Mass Loss (TML): Maximum 1.00%
- Volatile Condensable Material (VCM): Maximum 0.10%
- Weight Loss: Maximum 0.45%